Portable Electrical Insulation Helmet Testing Equipment / Instruments With LED Display
Product Details:
Place of Origin: | China |
Brand Name: | Gaoxin |
Model Number: | GX-7004 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1set |
---|---|
Price: | negotiation |
Packaging Details: | Non-fumigation wooden box |
Delivery Time: | 15 working days |
Payment Terms: | FOB Shenzhen, T/T |
Supply Ability: | 50 sets per month |
Detail Information |
|||
Friction Head: | Stainless Steel | Color: | Steel Grey |
---|---|---|---|
Displayer: | Meter | Capacity: | 60 Kg |
Feature: | Double Wing | Usage: | Test Electrical Insulation Of Safety Helmet |
Applicable Object: | Paper Packaging And Printing | Angle: | 90 Degree |
Highlight: | Professional Testing Equipment,automatic test equipment,Electrical Insulation Helmet Testing Equipment |
Product Description
Portable Electrical insulation Helmet Testing Equipment / Instruments with LED display
1. Quick Details:
Alternative name |
Electrical insulation tester for helmet |
Function |
Test electrical insulation property of helmet |
Feature |
Electric drive |
Weight |
135kg |
Volume |
86×43×80cm |
Test standard |
GB |
2. Description:
This tester is used to measure electrical insulation property of safety helmet.
Test method:
With preference of method B and method C, if the helmet passed both test, then It is qualified.
If there is blow hole or mental parts run through the helmet, then it is applicable to method A and method
C, and it pass two test taking as qualified.
The helmet has to be preprocessed before test.
Preprocessing method: soaked in the sodium cloride of 20℃±2℃ temperature and 3g/L density for 24
hours and take out, wipe dry the surface within 2min.
Method A:
Fix the helmet on the head shape mould.
Probe contact helmet and impose testing voltage, adjust the voltage to 1200V±25V and keep 15s, then
test again .
Each helmet will be tested 10 positions and record the value of current and possible punch through
phenomenon.
Method B:
Let the helmet upside down in an appropriate container, pour in sodium chloride liquid with density of 3g/L
till under helmet trim 10mm.
put probe in the liquid of inside of cap casing and outside respectively.
Rise the voltage to 1200V±25V and keep 15s.
record the value of current and possible punch through phenomenon.
Method C:
Contact the two probes on two any position and impose voltage, and the space between the two positions
not less than 20mm.
Adjust voltage to 1200V±25V within 1min.
Measure the leaking current between the positions and test again.
Each helmet will be tested 10 positions and record the value of current and possible punch through
phenomenon.
3. Features:
Water storage tank made of quality stainless steel.
LED digital display current and voltage.
5. Technical parameters:
Model |
GX-7004 |
Error of current value display |
±1% |
Error of voltage value display |
±1% |
Error of timer value display |
±1% |
Diameter of probe |
4mm, hemisphere |
Voltage regulator |
Measuring range 1500V |